Determination of Tensile Properties for Moulding and Extrusion Plastics (ISO 527-2, Part 2)

This part of  ISO 527 specifies the test conditions for determining the tensile properties of moulding and extrusion plastics.  These properties include ultimate strength, strain at failure, and modulus.  The mechanical properties of plastics can change dramatically when certain additives are incorporated into the formulation.  Some of these properties include strength, ductility, and toughness. For the measurement of modulus of elasticity, the speed of testing should be taken from the standard.
 
The following groups of materials are suitable for use with this method:  
  • Rigid and semi-rigid thermoplastics moulding, extrusion and cast materials in their unfilled form. This includes these materials reinforced with short fibers, small rods, plates, or granules, but excludes textile fibers.
  • Rigid and semi-rigid thermosetting molding and cast materials. This includes these materials reinforced with filler and reinforced compounds, but excludes textile fibers. 
  • Thermoplastic liquid crystal polymers.
All specimens should be made to the sizes specified in the standard and be free from visible surface flaws, including molding flash, shorts, or surface scratches.
 
As is the case with other materials, an extensometer is required to accurately measure strain.  A plastic stress curve versus strain curve most often contains a linear elastic region, as well as a non-linear plastic region.  Very little strain occurs within the linear region, and because modulus is measured within this region, extensometers with a high resolution are necessary.  Extensometers with high resolution typically have limited travel and must be removed from the specimen during a test.  Non-contacting extensometers such as the Advanced Video Extensometer (AVE) or Standard Video Extensometer (SVE) have the resolution and flexibility to measure modulus and strain to failure for most plastics. 
 
A suitable system for testing these types of samples would be to use an Instron 3300 or 5500 electromechanical testing machine with mechanical wedge grips. The choice of jaw faces may vary depending on sample type, but typically serrated faces are used. In addition to mechanical wedge grips, we also recommend pneumatic side-acting grips for testing plastics.

Über diese Lösung

Art der Prüfung: ISO 527-2
Art der Probe: Normprobestab, Vielzweckprobekörper
Materialien: Kunststoffe
Nach Material/Branche Zugprüfung
Geschäftsfeld: Luftfahrtindustrie und Zulieferer | Biomedizin, Medizinprodukte, Healthcare | Industrieprodukte, Endverbraucherprodukte

You are viewing a static image in place of an informative flash animation. Please download Adobe® Flash Player and refresh this page to view the animation.
Sind Sie an dieser Lösung interessiert?
Kontakt

Literatur zum Thema

2630 Series Strain Gauge Extensometers   2630 Series Strain Gauge Extensometers
2712 Series Pneumatic Action Grips (2712-017)   2712 Series Pneumatic Action Grips (2712-017)
2716 Series Manual Wedge Action Grips   2716 Series Manual Wedge Action Grips
3300 Series  -  Preiswerte Lösungen für die Werkstoffprüfung   3300 Series - Preiswerte Lösungen für die Werkstoffprüfung
Advanced Video Extensometer (AVE) (Cat.No. 2663-821)   Advanced Video Extensometer (AVE) (Cat.No. 2663-821)
ISO 527-2:1996   ISO 527-2:1996
Plastics Testing Solutions Brochure   Plastics Testing Solutions Brochure
Serie 5900 | Zuverlässige Prüfergebnisse   Serie 5900 | Zuverlässige Prüfergebnisse

Unsere Laboratorien

Die Instron Anwendungslaboratorien beschäftigen sich nicht nur mit Forschung und Entwicklung, sondern unterstützen auch durch Anwendungsbeispiele den Kunden bei der Auswahl des optimalen Prüfsystems.
Wenden Sie sich an unsere Anwendungsexperten und finden Sie